TWO PUMP "HI-LO" UNLOADING VALVES FLANGEABLE ON LOW-PRESSURE PUMP

TWO PUMP "HI-LO" UNLOADING VALVES FLANGEABLE ON LOW-PRESSURE PUMP

USE AND OPERATION
This valve is used in a 2 parallel-working pumps circuit in order to release the excess of the higher flow pump to the tank when this gets the required pressure setting. Since this moment and on, the actuator works with the lower flow pump at higher pressure, consuming less energy. This valve is designed for direct flanging on lower flow pump. To adjust the high pressure you have to mount an inline relief valve.

Body: Zinc-plated steel
Internal parts: Hardened and ground steel
Seals: Buna N standard
Tightness: Minor leakage.

Applications: Connect BP to the higher flow pump, AP to the lower flow pump, T to the tank, M to the eventual manometer and U as for necessity.
Click here to download a pdf of the Cartridge Valves section of our catalogue.
Logo
V0517 VEPFLP1/2", AP MAX FLOW L/MIN 15, BP MAX FLOW L/MIN 45, T MAX FLOW L/MIN 55, AP MAX PRESSURE BAR 350, BP MAX PRESSURE L/MIN 80, MAX PRESSURE BAR 350