In order to display the documentation in PDF format, Adobe Acrobat is required.
Harrier Fluid Power Ltd, Parys Road, Ludlow Business Park, Ludlow, Shropshire SY8 1XY United Kingdom Phone: 01584 876 033 Fax: 01584 876 044 Company Reg. No. 682 2498 09 Registered in England and Wales
USE AND OPERATION The relief valve provides overload protection in a fast and accurate way: when it reaches pressure setting, the valve opens allowing pressure relief in order not to exceed this setting. The differential valve opening is slower than the standard one, but the setting is more stable when the flow changes.
Body: Zinc-plated steel Internal parts: Hardened and ground steel Seals: Buna N standard Poppet type: minor leakage
Applications:Connect circuit port with pressure to P and tank port to T. The 1" size is supplied with a double exit T (1 exit can be capped according with mounting needs)